Does the Exposed Pad on the W25Q64JVZPIQ WSON Package Need to Be Grounded or Connected to Power?
The W25Q64JVZPIQ is supplied in an 8-pad WSON package measuring 6 × 5 mm. Like most WSON (Very Very Thin Small Outline No-lead) packages, it has a metal pad on the bottom center, often called the exposed pad or thermal pad. A common question during PCB layout is whether this pad must be connected to ground, connected to a power rail, or left floating. The answer from Winbond’s datasheet is explicit, and it differs in an important way from the design guidance often issued for WSON packages from other manufacturers.
1. What the W25Q64JVZPIQ Datasheet Actually Says
Winbond’s datasheet for the W25Q64JV family, including the WSON 6 × 5-mm package used by the W25Q64JVZPIQ, contains the following note: “The metal pad area on the bottom center of the package is not connected to any internal electrical signals. It can be left floating or connected to the device ground (GND pin). Avoid placement of exposed PCB vias under the pad.”[reference:0][reference:1]
This statement establishes three facts. First, the exposed pad has no electrical connection to the die or to any internal node of the Flash memory. It is not a ground pad, not a power pad, and not a signal pad in the electrical sense. Second, because it is electrically isolated internally, the designer has a choice: leave it floating or connect it to GND. Third, regardless of that choice, exposed vias should not be placed directly under the pad, a layout precaution related to solder voiding and manufacturing reliability rather than electrical function.
2. Why the Pad Exists at All
If the pad is not electrically connected, why is it there? WSON packages use a leadframe that is exposed on the bottom surface to provide a thermal path and to mechanically anchor the package to the PCB during reflow. The pad conducts heat from the die to the PCB copper, and it also forms a solder joint that improves the mechanical robustness of the leadless package. Winbond’s note that the pad “can be left floating or connected to the device ground” confirms that its primary role is thermal and mechanical, not electrical.
3. The Two Valid Options and Their Trade-offs
Option A: Connect the pad to GND. Although the pad has no internal electrical function, connecting it to the ground plane can still be beneficial. The ground connection lowers the thermal resistance from the die to the PCB by providing a larger heat-spreading area. It also reduces the risk of the pad acting as an unconnected metal region that could, in rare cases, couple noise or create a floating potential relative to the ground plane. For designs operating near the upper end of the temperature range, or for boards with limited copper area, grounding the pad is the more conservative choice.
Option B: Leave the pad floating. Because the pad is electrically isolated internally, leaving it floating does not affect the electrical performance of the Flash. This option may be chosen when the layout does not easily accommodate a ground connection to the pad, or when the designer wants to avoid any possibility of introducing a ground loop through the pad. Winbond explicitly permits this, so it is not a violation of the device specification.
What is not permitted: The pad must not be connected to a power rail or any potential other than ground. Although the datasheet says the pad “can be left floating or connected to the device ground,” it does not authorize connection to VCC. Connecting an electrically isolated thermal pad to a power rail serves no electrical purpose and can introduce unintended coupling or fault paths.
4. A Critical Distinction from Other WSON Packages
The guidance above is specific to the Winbond W25Q64JVZPIQ. It should not be generalized to every WSON package. Texas Instruments, for example, states in its WSON layout documentation that the exposed pad (DAP) is connected to the die substrate through a conductive die-attach adhesive, and that there is a parasitic PN junction between the substrate and device ground. As a result, TI “strongly recommends” that the DAP be connected directly to the device GND pin, and states that the DAP “must not be connected to any potential other than ground”[reference:2][reference:3]. The TI DAP is therefore not electrically isolated in the same way as the Winbond pad. The lesson is not that one manufacturer is right and the other is wrong; it is that the datasheet for the specific device must be consulted, because “WSON exposed pad” does not have a single universal electrical definition.
5. Design Summary
| Question | Answer for W25Q64JVZPIQ (WSON 6×5mm) |
|---|---|
| Is the exposed pad electrically connected to the die? | No. Winbond states it is not connected to any internal electrical signals[reference:4]. |
| Must the pad be grounded? | No. It can be left floating or connected to GND[reference:5]. |
| Can the pad be connected to VCC or another rail? | No. Only floating or GND are sanctioned. |
| Can exposed vias be placed under the pad? | No. Winbond explicitly advises against it[reference:6]. |
| What is the pad’s primary purpose? | Thermal and mechanical. It conducts heat to the PCB and anchors the package. |
| Does this apply to every WSON package? | No. TI WSON packages, for example, require the DAP to be grounded[reference:7]. |
6. Questions and Answers
Q: If the pad is electrically isolated, why does Winbond say it can be connected to ground?
A: Connecting it to ground is permitted because it does no electrical harm—the pad is isolated internally. The benefit is thermal and layout-related: a grounded pad can spread heat into the ground plane and avoid a floating metal region. It is a conservative choice, not an electrical requirement.
Q: What happens if I leave the pad floating?
A: Electrically, nothing changes. The Flash operates identically. The only potential concern is thermal: a floating pad relies on the solder joint alone for heat transfer, which is adequate for many applications but offers less margin than a grounded pad connected to copper. Winbond explicitly permits the floating option, so it is a valid design choice.
Q: Can I connect the pad to a 3.3V rail?
A: No. The datasheet authorizes only “floating” or “connected to the device ground (GND pin).” A power-rail connection is not among the permitted options. Even though the pad is electrically isolated internally, connecting it to a non-ground potential is outside the specified design envelope and serves no functional purpose.
Q: Why does TI require its WSON exposed pads to be grounded while Winbond does not?
A: The packages are constructed differently. In the TI WSON, the exposed pad is connected to the die substrate through a conductive adhesive, creating a parasitic junction to ground; grounding the pad is therefore necessary to control that junction. In the Winbond W25Q64JVZPIQ, the pad is not connected to any internal signal, so grounding is optional. The package name is the same; the internal construction is not.
7. Conclusion
For the W25Q64JVZPIQ in its 6 × 5-mm WSON package, the exposed pad is not an electrical terminal. Winbond’s datasheet permits it to be left floating or connected to GND, prohibits connection to any other potential, and advises against placing exposed vias beneath it[reference:8]. Grounding the pad is a reasonable thermal-layout choice; leaving it floating is equally valid electrically. The critical design rule is to read the specific device’s datasheet rather than applying a blanket “WSON pads must be grounded” assumption, because other manufacturers—Texas Instruments, for example—build their WSON packages with a different internal connection and issue the opposite recommendation.